Michell OptiCal Humidity Calibrator with competitive price
- Product Model:OptiCal Humidity Calibrator
- Country of origin:UK
- Delivery time:12 Weeks
- Weight:10Kg
- Product Description: Michell OptiCal Humidity Calibrator with competitive price
Product introduction
Michell OptiCal Humidity Calibrator with competitive price

Michell OptiCal Humidity Calibrator with competitive price
The OptiCal is a premium calibration solution for humidity sensors. The stand-alone and transportable calibrator requires no external services other than mains power, and features an integrated chilled mirror reference instrument to enable the operator to perform calibrations that are traceable to national standards. The calibration chamber features 5 interchangeable ports to accommodate virtually any brand, type or model of sensor.
Michell OptiCal Humidity Calibrator with competitive price
The environment within the insulated calibration chamber is temperature controlled using a 4-zone fan-assisted Peltier arrangement for maximum stability, and minimum temperature gradient. The humidity of the circulating air is precisely regulated using a closed-loop control system that functions by proportionally mixing flows of dry and saturated air.
Michell OptiCal Humidity Calibrator with competitive price
A bright and clear VFD (vacuum fluorescent display) displays the parameters measured by the reference instrument in various relative and absolute humidity units, alongside the temperature within the chamber. The humidity and temperature set-points can be controlled either manually or automatically as part of a calibration program.
Michell OptiCal Humidity Calibrator with competitive price
Manual control is achieved by the switches on the front panel and response time to a humidity or temperature step change is typically quicker than 10 minutes. The supplied application software allows calibration programs to be created, enabling automatic time-based control of temperature and humidity set points. The software also allows the user to monitor, chart and log calibration reference data on a PC for later analysis.
Michell OptiCal Humidity Calibrator with competitive price
Ordering Information

Michell OptiCal Humidity Calibrator with competitive price
The OptiCal is a premium calibration solution for humidity sensors. The stand-alone and transportable calibrator requires no external services other than mains power, and features an integrated chilled mirror reference instrument to enable the operator to perform calibrations that are traceable to national standards. The calibration chamber features 5 interchangeable ports to accommodate virtually any brand, type or model of sensor.
Michell OptiCal Humidity Calibrator with competitive price
The environment within the insulated calibration chamber is temperature controlled using a 4-zone fan-assisted Peltier arrangement for maximum stability, and minimum temperature gradient. The humidity of the circulating air is precisely regulated using a closed-loop control system that functions by proportionally mixing flows of dry and saturated air.
Michell OptiCal Humidity Calibrator with competitive price
A bright and clear VFD (vacuum fluorescent display) displays the parameters measured by the reference instrument in various relative and absolute humidity units, alongside the temperature within the chamber. The humidity and temperature set-points can be controlled either manually or automatically as part of a calibration program.
Michell OptiCal Humidity Calibrator with competitive price
Manual control is achieved by the switches on the front panel and response time to a humidity or temperature step change is typically quicker than 10 minutes. The supplied application software allows calibration programs to be created, enabling automatic time-based control of temperature and humidity set points. The software also allows the user to monitor, chart and log calibration reference data on a PC for later analysis.
Michell OptiCal Humidity Calibrator with competitive price
Ordering Information
We have good relationship with Michell. We already worked with them for 10 years with professional sales team. We can offer you the options based on your case accordingly.
If you have any inquiry about Michell analyzer, pls feel free to contact me.
Add:7-A16,Caishen Commercial Plaza,Hangkou Railway Station,Wuhan, China
M:86-15717178751(WhatsApp & Telegram) | T:+86-27-85887732 | F:86-27-85309780
Email:Jackie@hkxytech.com
If you have any inquiry about Michell analyzer, pls feel free to contact me.
Jackie Ma
HONGKONG XIEYUAN TECH CO., LIMITEDAdd:7-A16,Caishen Commercial Plaza,Hangkou Railway Station,Wuhan, China
M:86-15717178751(WhatsApp & Telegram) | T:+86-27-85887732 | F:86-27-85309780
Email:Jackie@hkxytech.com